Welcome To b2b168.com, Join Free | Sign In
中文(简体) |
中文(繁體) |
Francés |Español |Deutsch |Pусский |
| No.13642525
- Product Categories
- Friendly Links
Information Name: | Hangzhou automatic softener 6T / H |
Published: | 2015-01-22 |
Validity: | 360 |
Specifications: | 6 tons |
Quantity: | 56.00 |
Price Description: | |
Detailed Product Description: | Environmental Protection Equipment Co., Ltd. Hangzhou Frostsaber production of automatic water softener 6T developed for the treatment of the most suitable model, the controller for the import Flack, an Introduction water quality in the calcium and magnesium ions is called the total water total hardness, in daily life and industrial process water in the easy form insoluble precipitates (scale), will bring a lot of inconvenience to life and production, such as: high hardness scale cooling water will form a heat exchanger, a serious impediment water channel, the heat exchange effect is greatly reduced, but also produce perforation corrosion damage to equipment; scaling in the boiler heating surface will be used as boiler water when, while thermal deterioration; textile fabric will cause spots, affect the appearance of the product and quality and so on. Softener works by using ion exchange exchange interaction resin group, the water hardness components such as Ca2 +, Mg2 + plasma replacement removed to achieve water softening purposes, so that subsequent pipeline and internal equipment to reduce the scale to harm, to extend life of the equipment, the single-stage or multi-stage water hardness ≤0.02mmol after softening treatment / L, sodium softening failure need to regenerate, the operation is extremely convenient. Two, three automatic softener equipment, uses reverse osmosis, electrodialysis, ion exchange pretreatment pretreatment distiller variety of boiler water treatment treatment of water treatment plants and other industrial water treatment textile dyeing circulating water system to other water quality Water hardness required 255 / 440-268 / 440 controller installation Operating Instructions First, the installation steps: 1. The central tube and glue Used under good water distribution. The central tube into the glass drums aligned bottom center position, and then align the center of the glass tube at the interface drums up one centimeter cut central tube and glue transparent plastic, resin and then coming down the barrel, remove the clear plastic that is can. (After filling good resin) card into the water distribution and control joints with glue glue 4. 3. Pick up on the controller, centering tube, (remember the control ring) on ??the controller can be screwed. 5. After a series of controllers and resin tank, remove the salt cup, black float into the central portion of the salt cup, put both sides of the gong nailed tight. 6. After the salt cup Shang Hao, on the handle White (gong mother) into the suction tube tighten salt. The salt suction tube to the salt box, the inlet and outlet, outfall series of good, open the inlet valve 4/1, and so on to see full exhaust air after outfall can do debugging. 7. The time when the time was adjusted. (time disc) 8. The regeneration date sales by going to regenerate, the date of the pin pulled out for longer life. Please go to the beginning of the regeneration of the day aligned DAY location. (date disc) 9. disc regeneration program, the starting position * * * backwash position 10 minutes slow absorption of salt and 52 minutes * quick wash with salt water tank 10. 14 minutes after the completion of all the above steps, the program transfers WATER (water production location) turn on the tap connected to half a cup of water with a transparent cup, then drop 2-3 drops of reagent with demineralized water, if the water is completely softened blue represents water quality, water quality if the water is not completely softened purple representative (but also Qualified) ,. If the quality of the water quality does not soften the red (hard water) water softener requirements: water pressure: 2.75-5 kg ??of water hardness: 5mmol / L Water hardness: 0.03mmol / L regeneration salt consumption: 1L resin regeneration time consuming 160 grams of salt resin wear rate: 10-15% annualized ratio of the concentration of salt and water: 26/100 (ie, 26 kg of salt needs 100 kg of water to dissolve) |
Admin>>>
You are the 7825 visitor
Copyright © GuangDong ICP No. 10089450, Environmental Protection Equipment Co., Ltd. Hangzhou Frostsaber All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
You are the 7825 visitor
Copyright © GuangDong ICP No. 10089450, Environmental Protection Equipment Co., Ltd. Hangzhou Frostsaber All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility